The Comparison of Blood Glucose Check Results Using Photometer and Glucometer
##plugins.themes.academic_pro.article.main##
Abstract
Diabetes mellitus is a disease caused by high blood glucose levels. Blood glucose is a sugar that functions as an energy source for humans, formed from carbohydrates consumed and then stored as glycogen in the liver and muscles. Examining blood glucose levels can be done in two ways, namely using a photometer and a glucometer. This study aimed to determine differences in the results of blood glucose checks measured using a photometer and glucometer. The research was conducted with an analytic observational design with a cross-sectional approach. The study was conducted in June 2022. The population in this study were all Prolanis participants at the Klirong 1 Public Health Care Center. The sampling technique in this study used the accidental sampling technique. The data analysis used paired sample T-test. The results of the blood glucose checks using a photometer and glucometer showed a p-value (0.000) and alpha value (0.05). So it can be concluded that there is a significant difference between the results of blood glucose checks using a photometer and a glucometer.
##plugins.themes.academic_pro.article.details##
References
Balitbangkes. (2019). Laporan Provinsi Jawa Tengah Riskesdas 2018. In Kementerian Kesehatan Ri.
Endiyasa, E., Ariami, P., & Urip, U., (2019). Perbedaan Kadar Glukosa Darah Metode Poin Of Care Test (Poct) Dengan Photometer Menggunakan Sampel Serum Di Wilayah Kerja Puskesmas Jereweh. Jurnal Analis Medika Biosains (Jambs), 5(1), 40. Https://Doi.Org/ 10.32807/ 5i1.102
Firgiansyah, A. (2016). Perbandingan Kadar Glukosa Darah Menggunakan Spektrofotometer Dan Glukometer. Skripsi.
International Diabetes Federation 9th Edition. (2019). Global Diabetes Data Report 2010-2045. Journal Idf, 9(9), 1. Https://Diabetesatlas.Org/Data/En/World/
Iswanto, R. (2018). Perbandingan Hasil Pemeriksaan Kadar Asam Urat Menggunakan Metode Spketrofotometri Dan Metode Poct (Point Of Care Testing) Pada Pasien Puskesmas Poasia Kendari Sulawesi Tenggara (Sultra). Jurnal Medilab Mandala Waluya, 2(02), 9-13.
Kemenkes Ri. (2019a). Hari Diabetes Sedunia Tahun 2018. Pusat Data Dan
Informasi Kementrian Kesehatan Ri, 1–8.
Laisouw, A. J., (2017). Perbedaan Kadar Glukosa Darah Berdasarkan Tetesan Darah Kapiler Dan Hapusan Kapas Kering Metode Poct (Point-Of-Care-Testing). Thesis. File:///C://User/Downloads/Fvm939e.Pdf
Maini, R. (2020). Membandingkan Hasil Pemeriksaan Glukosa Darah Sewaktu Dengan Metoda Autoanalyzer Dan Point Of Care Testing Di Rsud M. Natsir (Doctoral Dissertation, Universitas Perintis Indonesia).
Rahmatunisa, A. N., Ali, Y., & Melani, E. (2021). Perbandingan Hasil Pemeriksaan Glukosa Darah Pada Serum Segera Dan Ditunda Selama 24 Jam. Prepotif: Jurnal Kesehatan Masyarakat, 5(2), 1180-1185.
Ramadhani, Qurotul Aini Nur Dkk.(2019). Perbedaan Glukosa Darah Sewaktu Menggunkan Serum Dan Plasma Edta.Jurnal Kesehatan Poltekkes Palembang.18(2), 80-84.
Sandy, M. E. (2021). Perbedaan Kadar Glukosa Darah Menggunakan Sampel Darah Vena Dan Darah Kapiler. Icme.
Sari, E. T. (2017). Perbedaan Hasil Pemeriksaan Kadar Glukosa Darah 2 Jam Pp Dengan Menggunakan Glukometer Dan Analyzer Pada Penderita Diabetes Melitus.
Ubaedillah, M. I. (2018). Perbedaan Kadar Glukosa Darah Sewaktu Dari Vena Dengan Dari Kapiler Menggunakan Alat Glukometer Metode Strip Pada Mahasiswa Akademi Analis Kesehatan An Nasher Cirebon.
Wulandari, J. (2019). Perbedaan Hasil Pemeriksaan Glukosa Darah Menggunakan Alat Poct Dengan Fotometer (Doctoral Dissertation, Poltekkes Kemenkes Kupang).