Effect of exposure factors on radiographic image quality in the use of abdominal phantom with ap projection
DOI:
https://doi.org/10.35335/midwifery.v11i2.1278Keywords:
Exposure Factors, Image Quality and Abdomen, RadiographyAbstract
Radiographic examination of the anatomy of the body can provide the maximum possible information that is easily determined by the Radiologist, if the quality of the radiographic image is good. To be able to produce radiographs that provide maximum information, optimal radiography is needed. In radiographic examinations, factors are needed that can affect the quality of photos in order to get better results. These factors include the exposure factor. The exposure factor consists of voltage (Kv), tube current (mA) and time (s). The purpose of the study was to determine the exposure factor on the quality of radiographic images on the use of abdominal phantoms with AP projections. The method used was experimental research. In some variations of the expulsion factor, there is no difference in quality both in terms of contrast and sharpness. The images produced from each variation are good and informative, so it can be assumed that the use of the exposure factor is chosen the most minimal so that the exposure or dose received is smaller. Image quality analysis should be made with a wider range of Kv and mAs, and using phantom objects other than abdominal phantoms.
Downloads
References
Al Shahrani, A. M. (2022). Projection Modification from Anterior–Posterior to Posterior–Anterior in the Abdomen Radiographic Examinations. Alfaisal University (Saudi Arabia).
Anggara, A. D. (2020). Pengaruh Faktor Eksposi Digital Radiography (DR) Terhadap Nilai Kontras Pada Citra Phantom Sebagai Organ Tiruan. Jurnal Fisika, 10(2), 19–26.
Anjani, A. D., Aulia, D. L. N., & Suryanti, S. (2022). Metodologi Penelitian Kesehatan.
ARYANI, N. P. (2022). Analisis Pengaruh Penggunaan Faktor Eksposi Terhadap Kualitas Citra Radiografi Phantom Air Berdasarkan Nilai Mean Square Error (MSE). UPEJ Unnes Physics Education Journal, 12(2), 115–119.
Ayu, R. G. (2018). Analisis Noise Berdasarkan Slice Thickness Dengan Teknik Irisan Axial Pada Citra Computed Tomography Scan (Ct-Scan).
Azam, M., & Dhahryan, D. (2009). Pengaruh Teknik Tegangan Tinggi Terhadap Entrasce Skin Exposure (ESE) dan Laju Paparan Radiasi Hambur Pada Pemeriksaan Abdomen. Berkala Fisika, 12(1), 21–26.
Bushong, S. C. (2020). Radiologic Science for Technologists E-Book: Physics, Biology, and Protection. Elsevier Health Sciences.
dan Pron, S. (2017). Radiation Dose Obtained from Abdominal Computed Radiography: Comparison Between Supine and Prone Positions. Jurnal Sains Kesihatan Malaysia, 15(2), 173–178.
Davies, B. H., Manning-Stanley, A. S., Hughes, V. J., & Ward, A. J. (2020). The impact of gonad shielding in anteroposterior (AP) pelvis projections in an adult: a phantom study utilising digital radiography (DR). Radiography, 26(3), 240–247.
Dewilza, N., Rad, A. M., Kes, M. T., Yudha, S., & Kes, M. T. (2023). Dasar-Dasar CT-Scan. Deepublish.
Gatt, S., Portelli, J. L., & Zarb, F. (2022). Optimisation of the AP abdomen projection for larger patient body thicknesses. Radiography, 28(1), 107–114.
Girsang, R. W. (2022). ANALISIS VARIAN TEGANGAN DAN WAKTU PENYINARAN PADA PESAWAT RONTGEN DI UNIT RADIOLOGI RSU. DELIMA MEDAN. Jurnal Hadron, 4(2), 30–35.
Gonydjaja, R. (2023). Pengantar Pengolahan Citra Digital. Penerbit P4I.
Haleem, A., & Javaid, M. (2019). 3D scanning applications in medical field: a literature-based review. Clinical Epidemiology and Global Health, 7(2), 199–210.
Jang, J. S., Yang, H. J., Koo, H. J., Kim, S. H., Park, C. R., Yoon, S. H., Shin, S. Y., & Do, K.-H. (2018). Image quality assessment with dose reduction using high kVp and additional filtration for abdominal digital radiography. Physica Medica, 50, 46–51.
Nehru, N. (2017). Pengaruh Faktor Eksposi Terhadap Kualitas Citra Radiografi. Journal Online of Physics, 3(1), 14–22.
Pradana, A. E. D. (2011). Pengukuran Penggunaan kV Pada Pemeriksaan Thorak Anak Terhadap Kualitas Gambar Dan Dosis Radiasi. Universitas Indonesia FMIPA, Jakarta.
Ramdhan, A. (2016). Klasifikasi Citra Rontgen Paru-Paru dengan Ekstraksi Fitur Histogram dan Metode Naive Bayes Classifier, S1. Vol, 3, 1–41.
Rilianti, D., & Oktarlina, R. Z. (2017). Radiografi Abdomen 3 Posisi pada Kasus Neonatus dengan Meteorismus. Jurnal Medula, 7(2), 42–47.
Rusyadi, L., Daryati, S., Rochmayanti, D., & Kurniawan, A. N. (2021). Analisis Noise Pada Radiografi Thorax Pulmonum Pada Penerapan Modifikasi Faktor Eksposi Aturan 10 kV. Jurnal Imejing Diagnostik (JImeD), 7(2), 70–76.
Sari, A. W., & Fransiska, E. (2018). Pengaruh faktor eksposi dengan ketebalan objek pada pemeriksaan foto thorax terhadap gambaran radiografi. Journal of Health (JoH), 5(1), 17–21.
Sinaga, M. (2006). Tantangan Badan Pengawas Mengimplementasikan Peraturan Penggunaan Pesawat Sinar-X untuk Diagnostik. Seminar Keselamatan Nuklir, 29–37.
Sriwahyuni, S. (2017). Pengaruh Tegangan Tabung (Kv) terhadap Kualitas Citra Radiografi Pesawat Sinar-X Digital Radiography (DR) pada Phantom Abdomen. SPEKTRA: Jurnal Fisika Dan Aplikasinya, 2(2), 113–118.
YANDI, D. (2021). PENGARUH VARIASI KV TERHADAP INFORMASI ANATOMI RADIOGRAF FEMUR DI INSTALASI RADIOLOGI RSUD ARIFIN ACHMAD PROVINSI RIAU.
Yudha, S., Kes, M. T., Dewilza, N., Rad, A. M., & Kes, M. T. (2023). Radiografi Digital. Deepublish.
Zelviani, S. (2017). Kualitas citra pada direct digital radiography dan computed radiography. Teknosains: Media Informasi Sains Dan Teknologi, 11(1).