Comparison of image quality between flexible coil and special purpose coil sagittal section on mri manus digit 2-3

Authors

  • Alya Verina Universitas Muhammadiyah Purwokerto, Indonesia
  • Hernastiti Sedya Utami Universitas Muhammadiyah Purwokerto, Indonesia
  • Fani Susanto Universitas Muhammadiyah Purwokerto, Indonesia
  • Fathur Rachmat Hidayat Universitas Muhammadiyah Purwokerto, Indonesia
  • Mochammad Syafi’ie RSUP Dr. Sardjito Yogyakarta, Indonesia
  • Alan Samudra Universitas Muhammadiyah Purwokerto, Indonesia

DOI:

https://doi.org/10.35335/midwifery.v13i1.1912

Keywords:

Flexible Coil, MRI Manus -α, Special Purpose Coil

Abstract

MRI examination of the manus has a challenge in obtaining optimal image quality. Good image quality depends on four characteristics, one of which is the Signal to Noise Ratio (SNR). SNR can be affected by the use of appropriate radiofrequency (RF) coils so that it can increase the SNR value. This study aims to analyze the impact of using different coils on SNR and CNR values, especially in sagittal sections of Proton Density Fat Sat scans. This study is a quantitative study using 10 volunteer samples in the period of February 2025. The results of the study show that the SNR value in the overall anatomy has a p-value <0.05 which means there is a significant difference using flexible coils and special purpose coils. While the SNR value in per-anatomy manus digits 2-3 has a significant difference except for the volar plate anatomy with a p-value = 0.121 meaning there is no significant difference. And compared to flexible coil, the use of special purpose coil in this study has a higher CNR value, especially in the anatomy of the Distal Interphalangeal Joint - Middle Phalanges with an average value of 1221.200. This study provides evidence that the selection of the right coil greatly affects the quality of the resulting image, and the use of special purpose coil is considered to produce better image quality. Therefore, the author recommends the use of special purpose coils in MRI examinations of the manus digits 2-3.

Downloads

Download data is not yet available.

References

Anggraini, D. T. (2021). Analisis Dukungan Suami dan Perilaku Ibu Nifas Dalam menggunakan KB Pasca Persalinan di Kecamatan Kisaran Barat Kabupaten Asahan. Universitas Islam Negeri Sumatera Utara.

Arifah, A. N., Kartikasari, Y., & Murniati, E. (2017). Analisis Perbandingan Nilai Signal to Noise Ratio (SNR) pada Pemeriksaan MRI Ankle Joint dengan Menggunakan Quad Knee Coil dan Flex/Multipurpose Coil. Jurnal Imejing Diagnostik (JImeD), 3(1), 220–224.

Arifah, A. N., Kartikasari, Y., & Murniati, E. (2021). Comparative Analysis of the Value of Signal To Noise Ratio (Snr) At Mri Ankle Joint Examination Using Quad Knee Coil and Flex/Multipurpose Coil. JImeD, 3(1), 220–224.

Dutton, M. (2015). Dutton’s Orthopaedic Examination, Evaluation, and Intervention.

Fatimah, S., binti Ismail, N. F., Masrochah, S., Dartini, S. K. M., Darmini, S. S., Aryani, A. I., & binti Ali, A. (2024). PENCITRAAN DIAGNOSTIK WANITA: PRINSIP, PATOLOGI UMUM DAN MODALITAS IMEJING. Cendikia Mulia Mandiri.

Hidayah, S., Sutanto, H., Rudi, D., & Thohir, S. (2015). Pengaruh Perubahan Tr Terhadap Nilai Cnr Dan Efisiensi Kontras Pada Citra Mri Head Sequence T1 Weighted Image. Youngster Physics Journal, 4(1), 93–98.

Jatmiko, A. W., Wandani, C. A., & Istigfarisky, L. W. (2021). Efek Pemakaian Kontras Untuk Optimalisasi Citra Pada Pemeriksaan Diagnostik Magnetic Resonance Imaging (MRI). Jurnal Biosains Pascasarjana, 23(1), 28.

John Lampignano, L. K. (2018). Textbook of Radiographic Positioning and Related Anatomy.

Johnson, D., & Stevens, K. J. (2015). A p p ro a c h t o M R I m a g i n g o f t h e El b o w a n d Wr i s t Technical Aspects and Innovation, 94305.

Juliantara, I. P. E., Herlina, W., & Triningsih, T. (2022). Optimalisasi Citra Mri Wrist Joint Dengan Penerapan 3D Isotropik Pada Pembobotan Proton Density Di Instalasi Radiologi Rsup Dr. M. Djamil Padang. Jurnal Syntax Admiration, 3(12), 1601–1611. https://doi.org/10.46799/jsa.v3i12.537

KARTAWIGUNA, D. (n.d.). PENGANTAR PENCITRAAN MEDIS.

Meraj, S., Gyftopoulos, S., Nellans, K., Walz, D., & Brown, M. S. (2017). MRI of the extensor tendons of the wrist. American Journal of Roentgenology, 209(5), 1093–1102. https://doi.org/10.2214/AJR.17.17791

Meylisyah, A. (2022). PENGGUNAAN ARANG AKTIF TEMPURUNG SIWALAN SEBAGAI MEDIA FILTRASI DALAM MENURUNKAN KESADAHAN AIR DI DESA LANCA KABUPATEN BONE= USE OF ACTIVE CHARCOAL OF SIWALAN TEMPURUNG AS FILTRATION MEDIA IN REDUCING WATER HARDNESS in LANCA VILLAGE, BONE REGENCY. Universitas Hasanuddin.

Mulyati, S., Rusyadi, L., Rahmawati, I. M. P., Fatimah, Wibowo, A. S., Indrati, R., & Rasyid. (2019). Differentiation Image Quality of MRI Shoulder Joint with Variation RF Coils. E3S Web of Conferences, 125(201 9), 7–11. https://doi.org/10.1051/e3sconf/201912518001

RANI, D. E. G. A. (2016). Optimalisasi Number Of Excitation (Nex) Terhadap Signal To-Noise Ratio (Snr) Dan Kecepatan Waktu Scanning Pada Pemeriksaan MRI. Universitas Airlangga.

Ringler, M. D., & Murthy, N. S. (2015). MR Imaging of Wrist Ligaments. Magnetic Resonance Imaging Clinics of North America, 23(3), 367–391. https://doi.org/10.1016/j.mric.2015.04.007

Salim, A. (2023). ANALISIS NILAI SNR DAN CNR PHANTOM HASIL PEMERIKSAAN CT-SCAN DENGAN METODE AXIAL DAN HELICAL DI RS HAJI MAKASSAR. Universitas Hasanuddin.

Su, T., Chen, Y., Zhang, Z., Zhu, J., Liu, W., Chen, X., … Jin, Z. (2020). Optimization of Simultaneous Multislice, Readout-Segmented Echo Planar Imaging for Accelerated Diffusion-Weighted Imaging of the Head and Neck: A Preliminary Study. Academic Radiology, 27(11), e245–e253. https://doi.org/10.1016/j.acra.2019.12.008

Tinungki, Y. L., Hairat, U., Rinarto, N. D., Supatmi, S., Destari, P. L., Zen, S., … Erawati, N. K. (2023). Buku Ajar Ilmu Biomedik Dasar. PT. Sonpedia Publishing Indonesia.

Umar, M. S., & Utama, J. P. (2021). Anatomi Tubuh Manusia. Samudra Biru.

Volland, N. A., Kholmovski, E. G., Parker, D. L., & Hadley, J. R. (2013). Initial feasibility testing of limited field of view magnetic resonance thermometry using a local cardiac radiofrequency coil. Magnetic Resonance in Medicine, 70(4), 994–1004. https://doi.org/10.1002/mrm.24534

Westbrook, C., & Talbot, J. (2018). Handbook of MRI Technique-Willey-Blackwell. Analytical Biochemistry (Vol. 11).

Westbrook, C., & Talbot, J. (2019). MRI in Practice. Sustainability (Switzerland) (Vol. 11).

Xiaoping Wu, Xiaotong Zhang, Jinfeng Tian, Sebastian Schmitter, Brian Hanna, John Strupp, Josef Pfeuffer, Michael Hamm, Dingxin Wang, Juegen Nistler, Bin He J, Thomas Vaughan, Kamil Ugurbil, and P.-F. V. de M. (2016). Comparison of radiofrequency body coils for MRI at 3 Tesla: a simulation study using parallel transmission on various anatomical targets. Physiology & Behavior, 176(1), 139–148. https://doi.org/10.1002/nbm.3378.Comparison

Yueniwati, Y., Putri, S. L., & Aurora, H. (2023). Magnetic Resonance Spectroscopy pada Otak: Prinsip dan Aplikasi Klinis. Universitas Brawijaya Press.

Downloads

Published

2025-04-25

How to Cite

Verina, A. (2025) “Comparison of image quality between flexible coil and special purpose coil sagittal section on mri manus digit 2-3”, Science Midwifery, 13(1), pp. 318–326. doi: 10.35335/midwifery.v13i1.1912.